Flash Point

SETA-CRM Abel Flash Point 40

The SETA-CRM Abel Flash Point 40 is an ISO 17034 UKAS accredited Abel Flash Point Certified Reference Material (CRM) with a nominal flash point value of 40 °C, designed for the verification of Abel Flash Point testers operating in accordance with IP 170, ISO 13736 and BS 2000-170.

Manufactured by Stanhope-Seta under the requirements of ISO 33405, with documentation compliant to ISO 33401, this hydrocarbon reference material has been characterised using an interlaboratory comparison procedure as defined in IP 170 Appendix D1. The Abel Flash Point Certified Reference Material provides laboratories with a reliable and traceable solution for routine instrument verification.

The CRM supports the annual verification requirements specified within IP 170 Appendix D1, helping laboratories maintain confidence in instrument performance while supporting ISO 17025 quality systems and audit requirements.

Each 100 mL bottle is supplied as a pack of 3 with an ISO 17034 certificate, Safety Data Sheet (SDS) and has a two-year shelf life from the date of manufacture.

Part Number:SETA-0412-0109
Methods: BS 2000-170, IP 170, ISO 13736

Amount

UKAS Reference Materials Certificate

The SETA-CRM range is designed to support routine instrument verification and ongoing performance monitoring. Each ISO 17034 Certified Reference Material is supplied with a certified value, measurement uncertainty, coverage factor and method limits, providing laboratories with the information needed to support ISO 17025 quality systems and demonstrate measurement traceability.

The 100 mL container is supplied with 85-95% ullage, meeting the requirements of IP 170 Section 8.2 and ensuring suitability for routine verification procedures.

In addition to routine quality control, SETA-CRMs can be used for operator training and competency assessment. Using a Certified Reference Material removes uncertainty when evaluating instrument performance, helping laboratories demonstrate competence during internal and external audits while reducing instrument downtime

Routine verification using the SETA-CRM Abel Flash Point 40 helps laboratories identify instrument drift before it affects reported flash point results, supporting reliable test data and ongoing compliance with IP 170 and ISO 17025 requirements.

Methods

MethodDetails
BS 2000-170Methods of test for petroleum and its products - Petroleum products. Determination of flash point. Abel closed cup method
IP 170Petroleum products and other liquids - Determination of flash point - Abel closed cup method (ISO 13736:1997)
ISO 13736Determination of flash point — Abel closed-cup method

Safety data sheets & Hazards

Part number Hazards Download Documents
SETA-0412-0109
Dangerous to Aquatic Environment icon Dangerous to Aquatic Environment
Flammable icon Flammable
Harmful Irritant icon Harmful Irritant
Health Hazard icon Health Hazard